ECS LITE SERIES

ECOSTREAM LITE SERIES IS BEST SUITAED FOR DRINKING WATER/ COMMERCIAL APPLICATIONS.THIS SERIES IS BEST UV DISINFECTION SOLUTION AT BUDGET PRICE.

Specification Details ECS04L ECS07L ECS15L ECS25L ECS40L ECS70L
Nominal Flow Rate (Post RO Disinfection) US Public Health (LPH) 400 LPH 650 LPH 1290 LPH 2600 LPH 4000 LPH 7000 LPH
AUV Standard (LPH) 250 LPH 400 LPH 750 LPH 1380 LPH 2100 LPH 4500 LPH
Inlet / Outlet Size ¼” BSP (M) ½” BSP (M) ¾” BSP (M) ¾” BSP (M) 1″ BSP (M) 1½” BSP (M)
Electrical Lamp Rating Watt 11 16 21 55 55 100
Length in MM 309 384 504 535 533 1024
Reactor Chamber MOC SS304L (Pickled, Passivated, and Electropolished)
Lamp Sleeve MOC High Purity Fused Quartz (99.99% Pure Silica; UVT > 95%)
O-rings and Seals MOC Food Grade EPDM (as per US FDA 21 CFR 177.2600)
Operating Voltage 230V / 50-60 Hz (±10%)
UV Lamp Failure Circuit Included
Lamp Power Supply Type Constant Current, High Frequency
(Specially Designed for UV Lamps)
Maximum Operating Pressure 75 psi
Recommended Water Temperature 18° – 40° Celsius

* All products are undergoing continuous improvements and
specifications subject to change at any time. Please consult Alfaa UV in case of any doubt.

ECS SERIES (SS 316 CHAMBER)

The UV IQ Series of UV systems has been introduced to address the need for a high performance but economically priced  UV system for the disinfection of drinking water and general purpose light industrial applications. The  UV IQ Series system is backed by the extensive R&D that goes into each and every Alfaa UV product, and the best in its class after sales service and support. UV technology can be a better and safer solution.

The UV IQ Series Platform encompasses our ECS, ETC, ECU and OZD series. Its modular design enables customization through mixing and matching of compatible components, allowing for tailored solutions to meet specific application and customer needs.

 

Model ECS 50ADQ ECS110 ADQ ECS 140ADQ ECS 170ADQ ECS 270 ADQ ECS 330 ADQ ECS 500ADQ
Recommended Flow (M³/HR) 3 6 8 10 16 20 30
UV Dose 30mJ/cm2 30mJ/cm2 30mJ/cm2 30mJ/cm2 30mJ/cm2 30mJ/cm2 30mJ/cm2
MOC of UV Reactor SS316L SS316L SS316L SS316L SS316L SS316L SS316L
Connection Size 1″ BSPP 1″ BSPP 1.5″ BSPP 2″ BSPP 1.5″ BSPP 2″ BSPP 3″ BSPP
UV Transmission Per CM 98% 98% 98% 98% 98% 98% 98%
Maximum Pressure 80 PSI 80 PSI 80 PSI 80 PSI 80 PSI 80 PSI 80 PSI
Recommended Temp 18-40 Degree C 18-40 Degree C 18-40 Degree C 18-40 Degree C 18-40 Degree C 18-40 Degree C 18-40 Degree C
Max Sanitization Temp (Lamp Off) 85 Deg C 85 Deg C 85 Deg C 85 Deg C 85 Deg C 85 Deg C 85 Deg C
O Ring and Seals MOC Food Grade EPDM Food Grade EPDM Food Grade EPDM Food Grade EPDM Food Grade EPDM Food Grade EPDM Food Grade EPDM
Quartz Jacket QUARTZ (UVT >95%) QUARTZ (UVT >95%) QUARTZ (UVT >95%) QUARTZ (UVT >95%) QUARTZ (UVT >95%) QUARTZ (UVT >95%) QUARTZ (UVT >95%)
Voltage 220-240 V / 50-60 Hz 220-240 V / 50-60 Hz 220-240 V / 50-60 Hz 220-240 V / 50-60 Hz 220-240 V / 50-60 Hz 220-240 V / 50-60 Hz 220-240 V / 50-60 Hz
Maximum Power Consumption 206W 206W 206W 206W 311W 311W 311W
Maximum Cable Length 4.5m 4.5m 4.5m 4.5m 4.5m 4.5m 4.5m
UV Lamp Failure Indication Included Included Included Included Included Included Included
Chamber Dimension 598 × 144 1103 × 137 1103 × 151 1103 × 151 1103 × 151 1103 × 175 1159 × 227
No of Lamps 1 1 1 1 2 2 2

WW SERIES

A uv system designed  for drinking pure water will not work in waste water.

The uv transmission of the water being disinfected is an essential factor while sizing a uv system.

WW series  is introduced to address the growing need for a reliable & environmentally responsible way to disinfect and reuse wastewater in these water starved times.

Unlike ordinary UV systems the WW Series is designed to effectively handle challenges posed by the complexity of tertiary treated wastewater having low UV transmission due to high amounts of BOD, COD and TSS.UV Technology ensures superior disinfection at lower capital and operating costs.


High Output Amalgam Lamp Technology

High Output Amalgam Lamp Technology

UV Technology   WW series uses high output Amalgam lamp technology to generate a higher UV dose to tackle high BOD, turbidity, and TSS. This results in a smaller footprint, simplified maintenance and lower operating costs.


UV Monitoring System (OPTIONAL)

A highly accurate and calibrated UV sensor encapsulated in a watertight stainless steel housing continuously measures the UV output within the reactor. It also triggers automated wiping cycles in order to self correct in case the drop in UV intensity is due to fouling of the quartz.

Our Waste Water UV Disinfection Series is designed to provide reliable and chemical-free disinfection for municipal and industrial wastewater treatment applications. Utilizing high-intensity ultraviolet technology, these systems effectively inactivate bacteria, viruses, and other microorganisms without altering water chemistry, making them an environmentally responsible solution for wastewater reuse and discharge compliance.

Manufactured with a robust SS316L stainless steel reactor chamber and high-purity quartz sleeves, the systems are engineered for continuous operation in demanding wastewater environments. The range covers flow capacities from 3 m³/hr to 42 m³/hr, ensuring suitability for small treatment plants as well as large-scale industrial facilities.

Key Features

  • UV Dose: 60 mJ/cm² for effective microbial disinfection
  • Reactor Material: SS316L Stainless Steel
  • High Purity Quartz Lamp Sleeves
  • Food Grade EPDM O-rings and Seals
  • UV Lamp Failure Indication Included
  • Operating Voltage: 220–240V, 50/60Hz
  • Maximum Operating Pressure: 80 psi
  • Recommended Water Temperature: 18°C – 45°C
  • Maximum Sanitization Temperature (Lamp Off): 85°C
  • Suitable for UV Transmittance up to 65% UVT
  • Cable Length: 4.5 m
  • Low maintenance and environmentally friendly operation
  • No chemicals, no by-products, and no change in taste, odor, or pH

Typical Applications

  • Municipal Wastewater Treatment Plants (STP)
  • Industrial Effluent Treatment Plants (ETP)
  • Water Reuse and Recycling Systems
  • Food & Beverage Processing
  • Pharmaceutical Industries
  • Textile and Chemical Industries
  • Cooling Tower Blowdown Treatment
  • Process Water Disinfection
  • Irrigation and Reclaimed Water Applications

Benefits

Our Waste Water UV Systems deliver consistent disinfection performance, reduced operating costs, and compliance with stringent wastewater discharge standards. The compact design, durable construction, and automated monitoring features ensure dependable operation with minimal maintenance requirements.

WWR Waste Water UV Disinfection Systems

Model Recommended Flow (m³/hr) No. of Lamps Connection Size Power Consumption
WW60ATQ 3 2 1.5″ BSPP (Male) 311 W
WW110ATQ 6 3 2.0″ BSPP (Male) 417 W
WW140ATQ 8 4 2.0″ BSPP (Male) 522 W
WW190ATQ 12 5 3.0″ BSPP (Male) 628 W
WW240ATQ 14 6 3.0″ BSPP (Male) 733 W
WW310ATQ 19 8 3.0″ BSPP (Male) 944 W
WW530ATQ 30 12 3.0″ BSPP (Male) 1367 W
WW700ATQ 42 16 3.0″ BSPP (Male) 1789 W

Standard Specification

Parameter Specification
UV Dose 60 mJ/cm²
Reactor Material SS316L Stainless Steel
UV Transmission 65%
Maximum Operating Pressure 80 psi
Recommended Water Temperature 18°C – 45°C
Maximum Sanitization Temperature (Lamp Off) 85°C
O-Rings & Seals Food Grade EPDM
Quartz Sleeve High Purity Quartz
Power Supply 220–240V, 50/60Hz
Cable Length 4.5 m
UV Lamp Failure Indication Included

Application

  • Sewage Treatment Plants (STP)
  • Effluent Treatment Plants (ETP)
  • Industrial Wastewater Treatment
  • Water Reuse & Recycling Systems
  • Food & Beverage Industries
  • Pharmaceutical Industries
  • Textile Industries
  • Municipal Wastewater Disinfection

API SERIES

API SERIES comes from Alfaa, company having vast experience and credibility for supply of UV systems for critical process water applications.

Today, this UV systems have earned the trust and goodwill of organizations such as Glaxo Smithkline Beecham, Ford Motors, Hindustan Lever Limited, Colgate Palmolive.

Features and Benefits of APi UV Lamp Series

  • Robust membrane keypad and user interface for all controller data.
  • UV Intensity and temperature monitoring and alarm with safety cutoff.
  • MODBUS (RS485) protocol for fully digital interconnect to PCs or PLCs.
  • Data logging of all critical UV parameters to compliant SCADA systems.
  • Resettable UV lamp hour counter.
  • System hour counter.
  • End-Of-Lamp-Life alarm.
  • Common fault contact.
  • Low UV contact.
Specification APi20 R1 APi35 R1 APi45 R1 APi70 R1
AUV Standard – 30 mJ/cm² 2.5 6.5 13 19
NSF / EPA – 40 mJ/cm² 2 5 10 18
Ozone Destruction – 120 mJ/cm² 0.65 1.6 3.3 6
Reactor (L×H) (mm) 1020 × 160 1020 × 170 1035 × 170 1035 × 185
Control Panel (W×H×D) (mm) 300 × 400 × 210 300 × 400 × 210 300 × 400 × 210 300 × 400 × 210
Voltage 220-240V / 50-60Hz 220-240V / 50-60Hz 220-240V / 50-60Hz 220-240V / 50-60Hz
Maximum Power Consumption (W) 167 284 206 362
Number of UV Lamps 1 2 1 2
Lamp Power (W) 105 210 140 280
Control Panel MOC Sheet Steel with Electrophoretic Dipcoat Priming and
Textured Powder Coating (optionally SS304)
Cabinet Cooling Mechanism Fan Cooled (with Filter)
Max. Lamp Cable Length (meters) 4.5
Reactor MOC Stainless Steel 316L
Sanitary Connections – Tri-Clamp (ASME-BPE-2009) 1″ 1.5″ 1.5″ 2″
Max. Operating Pressure 120 psi
Max. Operating Temperature 45 degrees C
Max. Sanitization Temperature 125 degrees C (lamps turned off)
UV Intensity Meter w/ 4-20 mA Output Optional
Internal Surface Finish Ra < 1 um Yes
Lamp Replacement Reminder Yes
Lamp Failure Indication (with Alarm) Yes

HF SERIES
Specification HF1 HF2 HF3 HF4 HF5 HF6 HF8 HF12
AUV Standard – 30 mJ/cm² 34 m³/hr 55 m³/hr 75 m³/hr 110 m³/hr 140 m³/hr 150 m³/hr 150 m³/hr 250 m³/hr
NSF / EPA – 40 mJ/cm² 26 m³/hr 42 m³/hr 56 m³/hr 85 m³/hr 105 m³/hr 130 m³/hr 150 m³/hr 230 m³/hr
Ozone Destruction – 120 mJ/cm² See technical specifications sheet for HiFlo HD Series
Voltage 220-240V / 50-60Hz 220-240V / 50-60Hz 220-240V / 50-60Hz 220-240V / 50-60Hz 220-240V / 50-60Hz 220-240V / 50-60Hz 220-240V / 50-60Hz 220-240V / 50-60Hz
Maximum Power Consumption (W) 512 873 1234 1595 1956 2317 3039 4484
Number of Lamps 1 2 3 4 5 6 8 12
Rating IP54
Control Panel MOC M.S. (optionally SS304)
Max. Lamp Cable Length (meters) 4.5
Reactor MOC Stainless Steel 316L
End Connections (ASA 150 RF Flanges) 3″ 4″ 4″ 6″ 6″ 6″ 6″ 8″
Max. Operating Pressure 120 psi
Max. Operating Temperature 45 degrees C
Max. Sanitization Temperature 125 degrees C (lamps turned off)
Lamp Replacement Reminder Yes
Lamp Failure Indication (with Alarm) Yes
UV Intensity Meter w/ 4-20 mA Output Optional
Automatic Wiper System Optional (must be ordered with UVM5000 option)
Sanitary TC End Connections Available
UV Intensity Meter with IntelliDose Yes
Nitrogen Purged UV Intensity Sensor (with Isolated Design) Yes
4-20 mA Output Signal Yes
RS485 / MODBUS Interface Yes
Built In Data Logging (3,000 records) Yes
Remote Lamp / On-Off (hardwire or MODBUS) Yes
Control Panel Temperature Control
(with automatic over temperature shutoff)
Yes (with automatic over temperature shutoff)
Reactor Temperature Control
(with automatic over temperature shutoff)
Yes (with automatic over temperature shutoff)
Automatic Wiping on Low UV Yes (automatic wiper system must be ordered)
Lamp Replacement Reminder with Pre-Alert Yes
Control Panel Safety Interlock Switch Yes

* When sizing for high dose (HD) application use the corresponding HD product code while ordering.